Instruments
Introduction
The Herschel science payload comprises three instruments that perform a combination of spectrometry, imaging spectrometry and imaging photometry covering a wavelength range from 55 to 672 µm.
Herschel's primary objectives are to:
- Study the formation of galaxies in the early Universe and their subsequent evolution
- Investigate the creation of stars and their interaction with the interstellar medium
- Observe the chemical composition of the atmospheres and surfaces of comets, planets and satellites
- Examine the molecular chemistry of the Universe
With its ability to observe across the far infrared and sub-millimetre wavelengths, Herschel furnishes observation data that has previously been unobtainable.
The instruments have been provided by collaborative efforts between scientific institutes in ESA member states, Canada and the USA. Principal Investigators in different countries led the nationally funded collaborations during the development of the respective instruments, and continue to lead the instrument consortia during the operational phase of the mission.
Herschel Instruments | ||
Instrument Name |
Instrument Description |
Principal Investigator |
Heterodyne Instrument for the Far Infrared (HIFI) | Very high resolution heterodyne spectrometer | Frank Helmich, SRON (Groningen, The Netherlands) |
Photodetector Array Camera and Spectrometer (PACS) | Imaging photometer / integral field line spectrometer | Albrecht Poglitsch, MPE (Garching, Germany) |
Spectral and Photometric Imaging Receiver (SPIRE) | Imaging photometer / imaging Fourier transform spectrometer | Matthew Griffin, University of Wales (Cardiff, United Kingdom) |
The instrument payload has been conceived and optimised with the prime science goals in mind, but in addition it offers a wide range of capabilities for the general observer.
Instruments in Brief
The Herschel scientific instrument complement comprises three instruments, two cameras (PACS and SPIRE) with additional imaging spectroscopy capabilities, and a very high-resolution heterodyne spectrometer (HIFI). The instruments were provided by three consortia led by their respective Principal Investigator.
Herschel Principal Investigators | |
HIFI |
Frank Helmich, SRON (Groningen, The Netherlands) |
PACS |
Albrecht Poglitsch, MPE (Garching, Germany) |
SPIRE |
Matthew Griffin, University of Wales (Cardiff, United Kingdom) |
Heterodyne Instrument for the Far Infrared (HIFI)
HIFI is a very high-resolution heterodyne spectrometer. The heterodyne detection principle involves translating the frequency range of the astronomical signal being observed to a lower frequency where it is easier to perform the required measurements. This is done by mixing the incoming signal with a very stable monochromatic signal, generated by a local oscillator, and extracting the difference frequency for further processing. HIFI observes in seven bands covering 480 to 1910 Ghz, or the wavelength range 157-625 µm. Bands one to five, which give continuous coverage from 480 to 1250 GHz, use superconductor-insulator-superconductor (SIS) mixers. Bands six low and six high cover 1410 to 1910 GHz and use hot electron bolometer (HEB) mixers.
HIFI Frequency Bands | |||
Band |
Mixer type |
Lower freq. |
Upper freq. |
1 |
SIS |
480 Ghz |
636 Ghz |
2 |
SIS |
634 Ghz |
804 Ghz |
3 |
SIS |
799 Ghz |
961 Ghz |
4 |
SIS |
949 Ghz |
1122 Ghz |
5 |
SIS |
1108 Ghz |
1280 Ghz |
6L |
HEB |
1426 Ghz |
1703 Ghz |
6H |
HEB |
1703 Ghz |
1907 Ghz |
The difference signal from the heterodyne process is passed to the instrument spectrometers housed in the service module.
There are four HIFI spectrometers, two Wide-Band acousto-optical Spectrometers (WBS) and two High Resolution autocorrelation Spectrometers (HRS). One of each spectrometer type is available for each polarization (vertical and horizontal polarization). All spectrometers can be used either individually or in parallel.
HIFI Spectrometers | |||
Spectrometer |
Wide band (2x) |
High resolution (2x) | |
Mode |
N/A |
Normal |
High Resolution |
Type |
Acousto-optical |
Autocorrelation | |
Bandwidth (GHz) |
4 |
0.23 |
0.23 |
Resolution (MHz) |
1.1 |
0.25 |
0.13 |
Velocity resolution (ms-1) |
680 - 220 |
170 - 90 |
110 - 80 |
Photodetector Array Camera and Spectrometer (PACS)
PACS is an imaging photometer and integral field line spectrometer. The instrument comprises two sub-instruments which offer the two basic and mutually exclusive modes:
In imaging dual-band photometry mode, PACS images a field of view of 1.75 × 3.5 arcminutes simultaneously in two bands, one of either
In integral field spectroscopy mode, PACS performs spectroscopy between 51 and 220 µm over a field of view of 47 × 47 arcseconds, resolved into 5 × 5 pixels. An image slicer employing reflective optics is used to re-arrange the two-dimensional field-of-view along a 1×25 pixels entrance slit for a grating. This PACS mode provides a resolving power between 1000 and 4000 (i.e. a spectral resolution of about 75-300 kms-1) depending on wavelength, with an instantaneous velocity coverage of about 1500 kms-1. The detectors for this mode are two germanium/gallium photoconductor arrays.
Spectral and Photometric Imaging Receiver (SPIRE)
SPIRE comprises a three band imaging photometer and an imaging Fourier transform spectrometer. SPIRE employs arrays of spider-web bolometers with neutron transmutation doped (NTD) germanium temperature sensors as its detectors.
The photometer images a 4 × 8 arcminute field of view on sky in three bands simultaneously.
SPIRE Photometer Characteristics | |||
Centre Wavelength (µm) |
250 |
350 |
500 |
λ/Δλ |
~ 3 |
~ 3 |
~ 3 |
Number of detectors |
139 |
88 |
43 |
Detector array size (mm) |
45 × 23 |
45 × 23 |
45 × 23 |
The photometer has three observing modes:
- Point source photometry
- Small area map; for sources or area with diameters smaller than 5 arcminutes
- Large area map; for covering large areas of sky or extended sources larger than 5 arcminutes across